74
RXL-W Series EDUS092213A
3P686875-1
5
Indoor Unit Installation
1. Installing the mounting plate
The mounting plate should be installed on a wall which can support the weight of the indoor unit.
1) Temporarily secure the mounting plate to the wall, make sure that the panel is completely level, and mark the drilling
points on the wall.
2) Secure the mounting plate to the wall with screws.
Recommended mounting plate retention spots and dimensions
30-5/16 (770)
Place the pipe port cover
in this pocket.
Gas pipe end
Through-the-wall
hole φ2-9/16 (65)
Recommended mounting plate
retention spots (7 spots in all)
Place a leveler
on these tabs.
1-3/4 (44.5)
1-3/4 (44.5)
1-7/8 (48)
11-1/4 (286)
11-1/4 (285)
6-11/16 (170)
1-7/8 (48)
1-15/16
(50*)
6-11/16
(170)
4-5/8 (116.5)
4-5/8 (117)
13-1/4 (337)
Drain hose position
Liquid pipe end
39 (990)
unit: inch (mm)
Gas pipe end
Through-the-wall
hole φ3-1/8 (80)
1-3/4 (44.5)
1-3/4 (44.5)
2-3/8 (60)
16-7/16 (417) 17-1/8 (435)
11-5/8 (295)
6-11/16 (170)
1-7/8 (48)
2-3/8 (60*)
6-11/16 (170)
5 (126.5)
4-5/8 (117)
Drain hose position
Liquid pipe end
Use a tape measure
as shown.
Position the end of
the tape measure at .
Place a leveler
on these tabs.
Recommended mounting plate
retention spots (7 spots in all)
The removed pipe
port cover can be
kept in the mounting
plate pocket.
Mounting
plate
Removed pipe
port cover
A
* Depending on the model, the actual distance between the liquid pipe end and gas pipe end may differ from the distance between those symbols on the
mounting plate (the distance listed in this manual).
Always measure the actual distance between the liquid pipe end and gas pipe end before installing refrigerant pipes.
09/12 class
15 class
01_EN_3P686875-1.indd 5 2022/04/28 11:02:35