SiBE041525F Functions
List of Functions 2
1. Functions
Category Functions
FTX20/25/35K(2)V1B
RX20/25/35K2/5V1B
FTX50/60/71K(M/2)V1B
RX50/60/71K(2)V1B
Category Functions
FTX20/25/35K(2)V1B
RX20/25/35K2/5V1B
FTX50/60/71K(M/2)V1B
RX50/60/71K(2)V1B
Basic
Functions
Inverter (with inverter power control) Health &
Cleanliness
Air-purifying filter — —
Operation limit for cooling (°CDB)
–10
~ 46
–10
~ 46
Photocatalytic deodorizing filter — —
Operation limit for heating (°CWB)
–15
~ 18
–15
~ 18
Air-purifying filter with photocatalytic
deodorizing function
——
PAM control
Titanium apatite photocatalytic
air-purifying filter
Standby electricity saving
Compressor Oval scroll compressor — — Air filter (prefilter)
Swing compressor Wipe-clean flat panel
Rotary compressor — — Washable grille — —
Reluctance DC motor MOLD PROOF operation — —
Comfortable
Airflow
Power-airflow flap — Good-sleep cooling operation — —
Power-airflow dual flaps — Timer WEEKLY TIMER operation — —
Power-airflow diffuser — — 24-hour ON/OFF TIMER — —
Wide-angle louvers Count up-down ON/OFF timer
Auto-swing (up and down) NIGHT SET mode
Auto-swing (right and left) — — Worry Free
(Reliability &
Durability)
Auto-restart (after power failure)
3-D airflow — — Self-diagnosis (R/C, LED)
COMFORT AIRFLOW operation Wiring error check function — —
Comfort
Control
Auto fan speed
Anti-corrosion treatment of outdoor
heat exchanger
Indoor unit quiet operation
Flexibility Multi-split / split type compatible
indoor unit
NIGHT QUIET mode (automatic) — — H/P, C/O compatible indoor unit — —
OUTDOOR UNIT QUIET operation
(manual)
——
Flexible power supply
correspondence
——
2-area INTELLIGENT EYE operation — — Chargeless 10 m 10 m
INTELLIGENT EYE operation — — Either side drain (right or left)
Quick warming function
(preheating control)
Power selection — —
Hot-start function
°C/°F changeover R/C temperature
display (factory setting: °C)
Automatic defrosting Remote
Control
5-room centralized controller (option)
Operation Automatic operation
Remote control adaptor
(normal open pulse contact) (option)
Program dry operation
Fan only
Remote control adaptor
(normal open contact) (option)
Lifestyle
Convenience
New POWERFUL operation
(non-inverter)
——
DIII-NET compatible (adaptor)
(option)
Inverter POWERFUL operation Remote
Controller
Wireless
Priority-room setting — — Wired (option)
COOL/HEAT mode lock — —
HOME LEAVE operation — —
ECONO operation
Indoor unit ON/OFF button
Signal receiving sign
R/C with back light — —
Temperature display — —
Note: : Available
— : Not available