EasyManua.ls Logo

Daikin FTX50K(M/2)V1B - Outdoor Unit; 20;25;35 Class

Daikin FTX50K(M/2)V1B
114 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SiBE041525F Outdoor Unit
Printed Circuit Board Connector Wiring Diagram 12
2. Outdoor Unit
2.1 20/25/35 Class
Main PCB (PCB1)
1) S20 Connector for electronic expansion valve coil
2) S30 Connector for compressor motor
3) S40 Connector for overload protector
4) S71 Connector for DC fan motor
5) S80 Connector for four way valve coil
6) S90 Connector for thermistors
(outdoor temperature, outdoor heat exchanger, discharge pipe)
7)
E1, E2 Terminal for earth wire
8) HL1, HN1, S Connector for terminal board
9) HR1, HR2 Connector for reactor
10)FU1, FU2 Fuse (3.15 A, 250 V)
11)FU3 Fuse (20 A, 250 V)
12)LED A LED for service monitor (green)
13)V2, V3, V150 Varistor
E1, E2
FU3
V150
V2
V3
FU1
FU2
HR1
HR2
S20
LED A
S90
S30 S40
HL1, HN1, S
S80 S71
2P383853-1

Table of Contents

Related product manuals