EasyManua.ls Logo

Daikin FTX50K(M/2)V1B - Inverter POWERFUL Operation

Daikin FTX50K(M/2)V1B
114 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Main Functions SiBE041525F
23 Functions and Control
1.10 Inverter POWERFUL Operation
Outline In order to exploit the cooling and heating capacity to full extent, the air conditioner can be
operated by increasing the indoor fan rotating speed and the compressor frequency.
Detail When the POWERFUL button is pressed, the fan speed and target temperature are converted
to the following states for 20 minutes.
A = 20/25/35 class: 80 rpm
50/60/71 class: 50 rpm
Ex: POWERFUL operation in cooling.
Note: POWERFUL operation cannot be used together with ECONO or COMFORT AIRFLOW
operation.
Operation mode Fan speed Target temperature
COOL H tap + A rpm 18°C
DRY Dry rotating speed + A rpm Lowered by 2.5°C
HEAT H tap + A rpm 31°C
FAN H tap + A rpm
AUTO Same as cooling / heating in
POWERFUL operation
The target temperature is
kept unchanged.
(R19177)
Target temp.
Fan
A rpm
18˚C
H tap
Set tap
20 minutes
It should be the lower limit of
cooling temperature.
It counts 20 minutes also
in the remote controller.
POWERFUL
ON
POWERFUL
OFF
Ending condition:
1. After the lapse of 20 minutes.
2. Operation OFF
3. POWERFUL operation is OFF.

Table of Contents

Related product manuals