ESIE16-02K | Part 3. Repair 3.3. Unit specific repair procedures
31/05/21 | Version 1.1 Page 73
RA R32 Split & multi split M-Series
Figure 3-11: Removing the switch box
Installation
1. Proceed in reverse order.
1. Insulation 6. Wire clamp
2. Main PCB 7. Screw
3. Electrical power wiring 8. Right side plate assembly
4. Wire terminals 9. Cable tie
5. Screw 10. Switch box
7 7 7
8
6
5
3
1 4
9
2 10