Forced Cooling Operation SiUS041829E
126 Part 7 Trial Operation and Field Settings
2. Forced Cooling Operation
Outline The forced cooling operation is allowed when both the following conditions are met.
1. The outdoor unit is not abnormal and not in the 3-minute standby mode.
2. The outdoor unit is not operating.
Protection functions have priority over all other functions during forced cooling operation.
Details With indoor unit ON/OFF switch
Press indoor unit ON/OFF switch for at least 5 seconds. The operation will start.
Forced cooling operation will stop automatically after about 15 minutes.
To stop the operation, press indoor unit ON/OFF switch.
R7000226
With the indoor unit's remote controller
1. Press Mode button and select the cooling operation.
2. Press On/Off button to turn on the system.
3. Press Temp, buttons and Mode button at the same time.
4. Press Temp, buttons, select "T", and press Mode button for confirmation.
Forced cooling operation will stop automatically after about 30 minutes.
To stop the operation, press On/Off button.
R7000227
Indoor unit
ON/OFF switch
1, 3, 4
3, 4
2
4

Table of Contents

Other manuals for Daikin FTXR-T Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Daikin FTXR-T Series and is the answer not in the manual?

Daikin FTXR-T Series Specifications

General IconGeneral
BrandDaikin
ModelFTXR-T Series
CategoryHeat Pump
LanguageEnglish

Related product manuals