EasyManua.ls Logo

Daikin FTXTA30C2V1BB - To Close the Front Panel; To Remove the Front Panel; To Take Following Items into Account before a Long Idle Period

Daikin FTXTA30C2V1BB
20 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8 Troubleshooting
Operation manual
18
FTXTA30C2V1B(W)(B)
Daikin room air conditioner
3P728539-2D – 2023.09
INFORMATION
Do NOT throw away the filter frame, but use it again.
Dispose of the old filter as non-flammable waste.
To order titanium apatite deodorising filter or silver particle filters,
contact your dealer.
Item Part number
Titanium deodorising filter KAF970A46
Silver particle filter KAF057A41
7.9 To close the front panel
1 Lift the front panel slightly and remove the support from the
fixing tab.
a
b
c
a Backside of the front panel
b Fixing tab
c Support
2 Close the front panel.
3 Gently press the front panel down until it clicks.
7.10 To remove the front panel
INFORMATION
Remove the front panel only in case it MUST be replaced.
1 Open the front panel. See "7.4To open the front panel"[416].
2 Open the panel locks located on the back side of the panel
(1on each side).
a a
a Panel lock
3 Push the right arm lightly to the right to disconnect the shaft
from the shaft slot on the right side.
a
c
b
a Arm
b Shaft
c Shaft slot
4 Disconnect the front panel shaft from the shaft slot on the left
side.
a
c
b
a Arm
b Shaft slot
c Shaft
5 Remove the front panel.
6 To re-install the front panel perform the steps in the opposite
order.
7.11 To take following items into
account before a long idle period
Operate the unit several hours in fan only mode to dry the inside of
the unit.
1 Press and select operation.
2 Press and start operation.
3 After operation stops, turn the breaker OFF.
4 Clean the air filters and replace them in their original positions.
5 Remove the batteries from the wireless remote control.
INFORMATION
It is recommended to have periodical maintenance
performed by a specialist. For specialist maintenance,
contact your dealer. Maintenance costs shall be borne by
the customer.
In certain operating conditions the inside of the unit may
get dirty after several seasons of use. This results in poor
performance.
8 Troubleshooting
If one of the following malfunctions occur, take the measures shown
below and contact your dealer.

Table of Contents

Other manuals for Daikin FTXTA30C2V1BB

Related product manuals