Si041137 Removal of Swing Motors (Pattern 2)
Removal Procedure 29
3
Detach the pivot from
the interlock shaft for
vertical blades with a
flat screwdriver.
4
Remove the swing
motor unit for vertical
blades.
5
Detach the interlock
shaft from the swing
motor with a flat
screwdriver.
6
Remove the vertical
blade interlock with a
flat screwdriver.
Step Procedure Points
(R13092)
Vertical blade
Pivot
Interlock
shaft
(R13125)
(R13126)
Interlock shaft
(R13127)
Vertical blade interlock