5 Operation
Operation manual
9
CVXM20+FVXM25~50A2V1B
Split system air conditioners
3P477071-2F – 2020.06
INFORMATION
When the unit is installed in a corner of a room, the
direction of the louvers should be facing away from the
wall. Efficiency will drop if a wall blocks the air.
5.5 Air outlet selection
Use this feature to let the unit decide automatically which air outlet
should be used or set the top air outlet only. The default setting is
automatic air outlet selection.
Setting Display Airflow direction
Automatic air
outlet selection
The unit decides automatically the
best air outlet depending on the
operation mode or room conditions.
Top air outlet
only
The airflow is set to top air outlet,
regardless of the operation mode or
room conditions.
Setting Operation
mode
Situation Air outlet selection
Drying Any situation
Cooling When the room
temperature
reaches the setpoint
or the total operation
time at high humidity
reaches 1 hour.
When the setpoint
temperature is NOT
reached yet, or the
total operation time
at high humidity is
less than 1 hour.
Heating, fan
only
Any situation
Drying,
cooling,
heating, fan
only
Any situation
INFORMATION
▪ During drying operation the airflow comes from the top
air outlet only. See "5.2 Operation mode and
temperature setpoint"[47] for setting.
▪ During Floor warming operation, the airflow comes from
the bottom air outlet only. See "5.6 Floor warming
operation" [4 9] for setting. Floor warming can be set
only with the automatic air outlet selection setting.
▪ If you change the setting from the automatic air outlet
selection to the top air outlet only in the heating
operation, heating is temporarily stopped to protect the
unit.
▪ Cooling/heating ability is lower when the top air outlet
only is set.
▪ While the air outlet selection is changing, a sound of
the moving damper can be heard.
5.5.1 To set automatic air outlet selection or
top air outlet only
Prerequisite: The default setting is automatic air outlet selection.
1 On the home screen, press for at least 2seconds.
Result: The selection menu appears. The menu number is
blinking.
2 Press or to select menu number .
3 Press to enter the setting.
Result: " " is blinking.
4 Press or to change the setting. " " = automatic air
outlet selection or " " = top air outlet only.
5 Press to confirm the selected setting.
Result: The setting is changed.
Note: The display automatically returns to the default screen after
1 minute. To return to the default screen sooner, press
twice.
5.6 Floor warming operation
This operation can effectively warm large floor areas by closing the
top air outlet and increasing the air velocity to reach distant floor
surfaces.
Normal operation Floor warming operation
INFORMATION
▪ Floor warming operation can be used in heating
operation mode only and with the automatic air outlet
selection setting.
▪ If the room temperature is low, the room may not get
warm enough.
5.6.1 To start/stop Floor warming operation
Prerequisite: This operation can be set only in heating operation
mode and with the automatic air outlet selection setting.
1 Press .
Result: is displayed on the LCD and the operation starts.
2 To stop operation, press .
Result: disappears from the LCD and operation stops.