EasyManuals Logo

Daikin FVXM35A3V1B9 Operation Manual

Daikin FVXM35A3V1B9
20 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #11 background imageLoading...
Page #11 background image
5 Operation
Operation manual
11
CVXM-A, FVXM-A, CVXM-A9, FVXM-A9, FVXTM-A
Split system air conditioners
3P477071-2M – 2022.09
Display Operation
Both deactivated
Powerful operation runs for 20 minutes; after that, operation
returns to the previously set mode.
Heat plus operation runs for 30 minutes; after that, operation
returns to the previously set mode.
2 To stop operation, press until both symbols disappear from
the LCD.
Note: Powerful operation and Heat plus can be set only when the
unit is running. If you press , operation will be cancelled; and
disappear from the LCD.
5.8 Econo and Outdoor unit quiet
operation
5.8.1 Econo operation
This is a function which enables efficient operation by limiting the
maximum power consumption value. This function is useful for cases
in which attention should be paid to ensure a circuit breaker will not
trip when the product runs alongside other appliances.
INFORMATION
Powerful, Heat plus, Floor warming and Econo
operation CANNOT be used at the same time. The last
selected function takes priority.
Econo operation is only available in automatic, cooling,
heating and drying operation modes.
Econo operation reduces power consumption of the
outdoor unit by limiting the rotation speed of the
compressor. If power consumption is already low,
Econo operation will NOT further reduce power
consumption.
5.8.2 Outdoor unit quiet operation
Use Outdoor unit quiet operation when you want to decrease the
noise level of the outdoor unit. Example: At night.
INFORMATION
Powerful, Heat plus, Floor warming and Outdoor unit
quiet operation CANNOT be used at the same time.
The last selected function takes priority.
Outdoor unit quiet operation is only available in
automatic, cooling, and heating operation.
Outdoor unit quiet operation limits the rotation speed of
the compressor. If the rotation speed of compressor is
already low, Outdoor unit quiet operation will NOT
further reduce the compressor rotation speed.
5.8.3 To start/stop Econo and Outdoor unit
quiet operation
1 Press one or more times.
Result: The setting will change as follows.
Display Operation
Econo
Outdoor unit quiet
+
Econo and Outdoor unit quiet
Display Operation
Both deactivated
2 To stop operation, press until both symbols disappear
from the LCD.
Note: Econo operation can be only set when the unit is running.
Pressing cancels the setting and disappears from the LCD.
Note: remains on the LCD, even if you turn off the unit using
the wireless remote control or indoor unit ON/OFF switch.
5.9 Flash Streamer (air cleaning)
operation
INFORMATION
The high-speed electrons are generated and go away
inside the unit to ensure safe operation.
The Streamer discharge may generate a fizzing sound.
If the airflow becomes weak, the Streamer discharge
may stop temporarily to prevent ozone smell.
5.9.1 To start/stop Flash Streamer (air cleaning)
operation
Prerequisite: Make sure the unit is operating ( is displayed on
the wireless remote control LCD).
1 Press .
Result: is displayed on the LCD and the air in the room is
cleaned when the unit is operating.
2 To stop operation, press .
Result: disappears from the LCD and operation stops.
INFORMATION
You can set the Flash Streamer operation when the
unit is both ON or OFF, but operation starts only when
the unit is operating.
When the setting is done while the unit is NOT
operating, is displayed on the wireless remote
control LCD, but operation does NOT start.
5.10 OFF/ON timer operation
Timer functions are useful for automatically switching the air
conditioner off/on at night or in the morning. You can also use OFF
timer and ON timer in combination.
There are two types of OFF/ON timer setting:
24 hour clock OFF/ON timer (default). The unit will stop/start
operating at the set time. Example: The ON timer is set to 13:30,
the unit will start operating at 13:30.
12 hour countdown OFF/ON timer. The unit will stop/start
operating after the set number of hours. Example: The ON timer
is set at 10:30 to 3 hours, the unit will start operating at 13:30.
Note: It is possible to combine both timer setting types.
INFORMATION
Program the timer again in case of:
A breaker has turned the unit off.
A power failure.
After replacing batteries in the wireless remote control.

Table of Contents

Other manuals for Daikin FVXM35A3V1B9

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Daikin FVXM35A3V1B9 and is the answer not in the manual?

Daikin FVXM35A3V1B9 Specifications

General IconGeneral
BrandDaikin
ModelFVXM35A3V1B9
CategoryAir Conditioner
LanguageEnglish

Related product manuals