5 | About the unit
Installer reference guide
19
CVXM-A, FVXM-A, CVXM-A9, FVXM-A9, FVXTM-A
Split system air conditioners
4P625991-1F – 2022.09
5 About the unit
WARNING: MILDLY FLAMMABLE MATERIAL
The refrigerant inside this unit is mildly flammable.
5.1 System layout
a Indoor unit
b Drain piping
c Refrigerant piping (gas and liquid)
d Outdoor unit
5.2 Operation range
Use the system in the following temperature and humidity ranges for safe and
effective operation.
CVXM, FVXM
Cooling and drying
(a)(b)
Heating
(a)
Indoor temperature 18~32°C DB
14~23°CWB
10~30°CDB
Indoor humidity ≤80%
(b)
—
(a)
A safety device might stop the operation of the system if the unit runs outside its
operation range.
(b)
Condensation and water dripping might occur if the unit runs outside its operation range.
FVXTM
Cooling and drying
(a)(b)
Heating
(a)
Indoor temperature 18~32°C DB
14~23°CWB
10~30°CDB
Indoor humidity ≤80%
(b)
—
(a)
A safety device might stop the operation of the system if the unit runs outside its
operation range.
(b)
Condensation and water dripping might occur if the unit runs outside its operation range.