4.
DEHUMIDIFICATION CONTROL SETTING
This unit features the dehumidification function. Therefore, it is necessary to set whether the
dehumidification control is to be executed or not according to the cargo to be transferred.
You can set whether the dehumidification control is to be executed or not by operating the display
panel of controller.
4.1 Description of setting
Whether the dehumidification control is to be executed or not is switched over according to the setting
of dehumidification control parameter "dHu" under the "4. G-SET operation / Automatic pump down
operation mode / Dehumidification ON-AOFF setting"
CAUTION
1ON/OFF of the reheating coil and DE-HUMID LED lit/unlit are not
synchronous.
2To apply the humidification control, be sure to set "ON-A".
Dehumidification
control
Setting of
dehumidification
control "dHu"
DE-HUMID LED Remarks
To execute ON-A (Applied) ON
Case of the unit without the
humidity sensor
Not to execute
off (Not applied)
OFF
Note) The setting of dehumidification control can also be mode while in optional functional setting
mode. (Refer to 3.3.3 of service manual on page 3-26.)