EasyManua.ls Logo

Daikin Siesta ATXM20N2V1B - Operation

Daikin Siesta ATXM20N2V1B
56 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5 | Operation
User reference guide
17
ATXM20~50N2V1B
Daikin room air conditioner
4P518786-2F – 2020.05
5 Operation
5.1 Operation range
Use the system in the following temperature and humidity ranges for safe and
effective operation.
In combination with outdoor units: 2AMXM and 3AMXM
Cooling and drying
(a)
Heating
(a)
Outdoor temperature –10~46°CDB –15~24°CDB
–15~18°CWB
Indoor temperature 18~37°C DB
14~28°CWB
10~30°CDB
Indoor humidity ≤80%
(b)
In combination with other outdoor units
Cooling and drying
(a)
Heating
(a)
Outdoor temperature –10~50°CDB –20~24°CDB
–21~18°CWB
Indoor temperature 18~37°C DB
14~28°CWB
10~30°CDB
Indoor humidity ≤80%
(b)
If operated outside the operation range:
(a) A safety device might stop the operation of the system.
(b) Condensation might occur on the indoor unit and drip.
5.2 When to use which feature
You can use the following table to determine which features to use:¨
INFORMATION
Operation modes: cooling, drying and automatic are NOT available for the heating
only version of the product.
Feature Tasks
Basic features

Table of Contents

Related product manuals