7 | Maintenance and service
User reference guide
39
ATXM20~50N2V1B
Daikin room air conditioner
4P518786-2F – 2020.05
7.4 To remove the front panel
1 Hold the front panel by the panel tabs on both sides and open it.
a Panel tabs
2 Remove the front panel by sliding it to the left or the right and pulling it
toward you.
Result: The front panel shaft on 1 side will be disconnected.
3 Disconnect the front panel shaft on the other side in the same manner.
a Front panel shaft
7.5 About the air filters
Operating the unit with dirty filters means that the filter:
▪ CANNOT deodorize the air,
▪ CANNOT clean the air,
▪ poor heating/cooling,
▪ causes odour.
7.6 To clean the air filters
1 Push the tab at the centre of each air filter, then pull it down.
2 Pull out the air filters.
Note: (class 50) The titanium apatite deodorizing filter MUST be removed before
cleaning the air filter.
3 Remove the titanium apatite deodorizing filter from all 4 claws.