11 Technical data
Installation manual
20
RZASG100~140MUV/Y
Sky Air Advance-series
4P734658-1 – 2023.08
11.3 Wiring diagram: Outdoor unit
The wiring diagram is delivered with the unit, located at the inside of
the service cover.
(1) Connection diagram
English Translation
Connection diagram Connection diagram
Only for *** Only for ***
See note *** See note ***
Outdoor Outdoor
Indoor Indoor
Upper Upper
Lower Lower
Fan Fan
ON ON
OFF OFF
(2) Layout
English Translation
Layout Layout
Front Front
Back Back
Position of compressor terminal Position of compressor terminal
(3) Notes
English Translation
Notes Notes
Connection
X1M Indoor/outdoor communication
Earth wiring
Field supply
1
Several wiring possibilities
Protective earth
Field wire
Wiring depending on model
Option
Switch box
PCB
NOTES:
1 Refer to the wiring diagram sticker (on the back of the front
plate) for how to use the BS1~BS3 and DS1 switches.
2 When operating, do not short-circuit protective devices S1PH
S1PLand Q1E.
3 Refer to the combination table and the option manual for how
to connect the wiring to X6A, X28A and X77A.
4 Colours: BLK: black, RED: red, BLU: blue, WHT: white, GRN:
green, YLW: yellow.
(4) Legend
English Translation
Legend Legend
Field supply Field supply
Optional Optional
Part n° Part n°
Description Description
A1P Printed circuit board (main)
A2P Printed circuit board (noise filter)
BS1~BS3 (A1P) Push button switch on PCB
C* (A1P) (Y only) Capacitor
DS1 (A1P) Dipswitch
E* (A1P) Terminal (noiseless earth)
F*U Fuse
H*P (A1P) Light-emitting diode (service monitor is
green)
K1M, K3M (A1P) (Y
only)
Magnetic contactor
K1R (A1P) Magnetic relay (Y1S)
K2R (A1P) Magnetic relay (Y2S)
K10R, K13R~K15R
(A1P)
Magnetic relay
K11M (A1P) (V only) Magnetic contactor
L* (A1P) Terminal (live)
L1R (Y only) Reactor
M1C Compressor motor
M1F Fan motor
N* (A1P) Terminal (neutral)
PFC (A1P) (V only) Power factor correction
PS (A1P) Switching power supply
Q1 Overload protection
Q1DI Earth leakage circuit breaker (30mA)
R1~R8 (A1P) (Y only) Resistor
R1T Thermistor (air)
R2T Thermistor (discharge)
R3T Thermistor (suction)
R4T Thermistor (heat exchanger)
R5T Thermistor (heat exchanger middle)
R6T Thermistor (liquid)
R7T Thermistor (fin)
R8T~R10T (A1P ) Thermistor (PTC)
R11T (A1P ) (Y only) Thermistor (PTC)
R501~R962 (A1P )
(V only)
Resistor
R2~R981 (A1P ) (Y
only)
Resistor
R*V (A2P ) (V only) Varistor
S1PH High pressure switch
S1PL Low pressure switch
SEG* (A1P) 7-segment display
TC1 (A1P) Signal transmission circuit
V1D (A1P) (V only) Diode
V1D~V2D (A1P) (Y
only)
Diode
V*R (A1P) Diode module/ IGBT power module
X*A Connector
X1M Terminal strip
Y1E, Y3E Electronic expansion valve
Y1S Solenoid valve (4‑way valve)
Y2S Solenoid valve (gas receiver)
Z*C Noise filter (ferrite core)
Z*F Noise filter