EasyManua.ls Logo

Daikin Super Multi NX B series - Indoor Units - Cooling Only

Daikin Super Multi NX B series
302 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Specifications Si12-308
20 Specifications
1. Specifications
1.1 Indoor Units - Cooling Only
Wall Mounted Type
50Hz 220-230-240V / 60Hz 220-230V
Model FTKE25BVM FTKE35BVM
Rated Capacity 2.5kW Class 3.5kW Class
Front Panel Color White White
Air Flow Rates
m³/min
(cfm)
H 7.8 (275) 7.7 (272)
M 6.4 (226) 6.3 (222)
L 5.0 (177) 4.9 (173)
SL 4.3 (152) 4.4 (155)
Fan
Type Cross Flow Fan Cross Flow Fan
Motor Output W 18 18
Speed Steps 5 Steps, Silent and Auto 5 Steps, Silent and Auto
Air Direction Control Right, Left, Horizontal and Downward Right, Left, Horizontal and Downward
Air Filter Removal-Washable-Mildew Proof Removal-Washable-Mildew Proof
Running Current (Rated) A 0.17-0.18-0.18/0.21-0.21 0.17-0.18-0.18/0.21-0.21
Power Consumption (Rated) W 37-40-43/45-48 37-40-43/45-48
Power Factor % 98.9-96.6-99.5/97.4-99.4 98.9-96.6-99.5/97.4-99.4
Temperature Control Microcomputer Control Microcomputer Control
Dimensions (H×W×D) mm 273×784×195 273×784×195
Packaged Dimension mm 834×325×258 834×325×258
Weight kg 7.5 7.5
Gross Weight kg 11 11
Operation
Sound
H/M/L/SL dBA 37/34/30/27 38/35/32/29
Heat Insulation Both Liquid and Gas Pipes Both Liquid and Gas Pipes
Piping Connection
Liquid mm
φ
6.4
φ
6.4
Gas mm
φ
9.5
φ
12.7
Drain mm
φ
18.0
φ
18.0
Conversion Formulae
kcal/h=kW×860
Btu/h=kW×3414
cfm=m³/mi35.3
Model FTKD50BVM FTKD60BVM
Rated Capacity 5.0kW Class 6.0kW Class
Front Panel Color White White
Air Flow Rates
m³/min
(cfm)
H 16.8 (593) 17.5 (618)
M 14.0 (494) 14.6 (515)
L 11.8 (417) 12.2 (431)
SL 10.4 (367) 10.8 (318)
Fan
Type Cross Flow Fan Cross Flow Fan
Motor Output W 43 43
Speed Steps 5 Steps, Silent and Auto 5 Steps, Silent and Auto
Air Direction Control Right, Left, Horizontal and Downward Right, Left, Horizontal and Downward
Air Filter Removal-Washable-Mildew Proof Removal-Washable-Mildew Proof
Running Current (Rated) A 0.19-0.18-0.17/0.19-0.18 0.21-0.20-0.19/0.21-0.20
Power Consumption (Rated) W 40-40-40/40-40 45-45-45/45-45
Power Factor % 95.7-96.6-98.0/95.7-96.6 97.4-97.8-98.7/97.4-97.8
Temperature Control Microcomputer Control Microcomputer Control
Dimensions (H×W×D) mm 290×1,050×238 290×1,050×238
Packaged Dimension mm 1,147×366×337 1,147×366×337
Weight kg 12 12
Gross Weight kg 17 17
Operation
Sound
H/M/L/SL dBA 44/40/35/32 45/41/36/33
Heat Insulation Both Liquid and Gas Pipes Both Liquid and Gas Pipes
Piping Connection
Liquid mm
φ
6.4
φ
6.4
Gas mm
φ
12.7
φ
15.9
Drain mm
φ
18.0
φ
18.0

Table of Contents