Refrigerant | R-410A |
---|---|
Compressor Type | Scroll |
Type | Air-cooled scroll chiller |
Power Supply | 400V, 50Hz, 3 Phase (Varies by model, check specific model) |
Dimensions | Varies by model |
Weight | Varies by model |
Details the different models available in the UAL series, including cooling capacity and max combination quantity.
Explains the coding system used for model names, breaking down each component of the designation.
Highlights key features of the UAL R410A series, covering refrigerant, installation, and performance.
Units can be combined in sets of 1-10 for flexible capacity matching.
User-friendly system with microchip and LCD display for swift, easy control.
Provides detailed technical specifications for the UAL160A5 and UAL210A5 models.
Details the specifications of individual components used in the UAL series chillers.
Presents electrical characteristics such as voltage, current, power output, and fan speed.
Lists the safety devices integrated into the unit, including pressure switches and sequencers.
Provides dimensional drawings and measurements for different UAL series models.
Defines the cooling mode operating limits based on ambient and leaving water temperatures.
Graphical representation of cooling capacity correction factors based on ambient and water temperatures.
Graphical representation of cooling capacity correction factors based on ambient and water temperatures.
Illustrates the water pressure drop across the unit as a function of water flow rate.
Presents octave band sound levels and overall dB(A) values for the units under specific test conditions.
Covers working conditions, installation dimensions, environment limits, and unit space allocation.
Provides general notes on installation, securing, and hoisting procedures for the chiller unit.
Details water quality requirements, system diagrams, and flushing procedures for water system setup.
Guidelines for pipe design, water storage tank, and circulation pump selection.
Covers pre-turn-on checks and pilot run verification steps for the unit.
Details repair procedures, periodic checks, and a routine maintenance plan for unit upkeep.
Explains different water system types (re-circulation, once-through) and their processing methods.
Details power cable connections, PCB instructions, DIP switch setup, and communication.
Provides dimensions and installation guidance for the wired controller unit.
Describes controller features, settings management, timer functions, and defrost/reset operations.
Lists error codes, symptoms, and corresponding codes for unit malfunctions.
Provides solutions for common issues like communication failures, overloads, and sensor problems.
Important warnings regarding product export, installation by qualified personnel, and use of specified parts.
Advice on avoiding corrosive environments and sea breeze exposure for product longevity.