73
Steam probe short circuit
CAUSE
This alarm is triggered when
MCS temperature probe is out
of the range.
EFFECT
MCS function is locked; push DEL
on display to delete the alarm.
Gr.1 probe time-out
CAUSE
This alarm is triggered when
group 1 does not reach the tem-
perature of 50°C within 5 minu-
tes of turning on.
EFFECT
Group 1 heating up is locked;
push DEL on display to delete
the alarm.
Gr.1 probe interrupted
CAUSE
This alarm is triggered when
group 1 temperature probe is
out of the range.
EFFECT
Group 1 heating up is locked;
push DEL on display to delete
the alarm.
Gr.1 probe short circuit
CAUSE
This alarm is triggered when
group 1 temperature probe is
out of the range.
EFFECT
Group 1 heating up is locked;
push DEL on display to delete
the alarm.
Gr.1 high temp.
CAUSE
This alarm is triggered when
group 1 temperature exceeds
120°C.
EFFECT
Group 1 heating up is locked;
push DEL on display to delete
the alarm.
Gr.2 probe time-out
CAUSE
This alarm is triggered when
group 2 does not reach the tem-
perature of 50°C within 5 minu-
tes of turning on.
EFFECT
Group 2 heating up is locked;
push DEL on display to delete
the alarm.