Instruction CF-RS Standard Room Thermostat
Initiate transmission test on Room
Thermostat - g. 1
• Press the push button
• LED goes ON
Link test is satisfactory
• LED goes OFF
Link test is unsatisfactory
• LED ashes 5 times
No Link connection to Room
Thermostat
Try to relocate Room Thermostat in the room
Or install Repeater Unit (CF-RU) and locate be-
tween Master Controller and Room Thermostat
Note: Master Controller output LED(s) connect-
ed to the room thermostat, ash(es) during Link test