EasyManuals Logo
Home>Danfoss>Water Pump>APP series

Danfoss APP series Service Guide

Danfoss APP series
12 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #8 background imageLoading...
Page #8 background image
Service guide | Disassembling and Assembling, APP(W) 5.1-10.2
© Danfoss | DCS (im) | 2017.068 | 180R9238 | DKCFN.PI.078.F3.02 | 521B1196
5. Change of shaft seal
1. Unscrew the seal retaining ring
counterclockwise and remove it.Tools provided according to 180B4162
3. Carefully remove the flange from the
casing.
4. Wet the shaft and shaft seal with clean
filtered water.
2. Unscrew the 8 screws in the mounting
flange.
5. Carefully remove the shaft seal assembly
using the shaft-seal extractor supplied.
The extractor must fit underneath the
shaft seal.

Other manuals for Danfoss APP series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss APP series and is the answer not in the manual?

Danfoss APP series Specifications

General IconGeneral
BrandDanfoss
ModelAPP series
CategoryWater Pump
LanguageEnglish

Related product manuals