When installing the connection box lid, make sure there are no foreign particles between the
connection box lid and the insulation and that all connection box fasteners are in place.
Missing or loose screws can compromise the insulation.
Make sure the power cables exit straight from the terminals and do not rub against the sharp
cable through-holes or other sharp edges which could wear out the cable insulation over
time.
Do not place any excess weight on the connection box lid(s).
The high voltage cables of the electric machine are connected to the connection box(es) of the electric
machine. The Figure below shows the components of the high voltage connection box assembly.
1.
Remove the cover of the terminal box.
2.
Install the power cables.
3.
Install the cover of the terminal box back.
High voltage connection assembly structure
Part Number Qty Description Type
24 12 Bolt, socket head M6 x 16, ISO 7380, A4-70
25 1 Plate, T=5 Gasket extruding
26 3 Nut M8, DIN 934, Zinked