EasyManua.ls Logo

Danfoss EM-PMI375 - Mounting the Electric Machine

Danfoss EM-PMI375
83 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Allowed horizontal mounting positions, front view
Mounting the electric machine
Do not exceed the maximum axial and radial forces calculated for the shaft.
Document Allowed bearing loads for EM-PMI machines DOC-000454 gives more
information about this. Contact Danfoss to obtain the document.
Do not use the N-end of the electric machine for mounting the electric machine.
Refer to Chapter Allowed mounting positions for the correct mounting positions of the electric
machine.
Mount the electric machine on a correct supporting structure as discussed in Chapter Supporting structure
requirements.
Horizontal assembly
1. Lift the electric machine to the correct mounting position. See Chapter Lifting for details.
2. The electric machine is mounted from its D-end flange (SAE3 transmission housing flange). SAE3
flywheel housing is required as a mating flange.
3. Align the electric machine with the mating housing alignment. See Chapter Shaft alignment and load.
4. Connect the shaft of the electric machine, make sure to use full spline engagement. Lubricate the
spline.
A recommended spline lubricant is a 50/50 compound of a high temperature grease and a
molybdenum disulphide powder. When applied initially and re-applied at proper intervals, it
will help prevent fretting corrosion and premature wear. This lubricant is not soluble in oil
and should be used accordingly. Further products which may be recommended are Molycote,
Metaflux, Never Seeze, Optimol and similar.
5. Attach the mounting bolts. For steel housing the minimum length of the bolt is 35 mm and for
aluminum housing 40 mm. (40 mm and 45 mm for EM-PMI375-T800).
User Guide
EM-PMI375
Installation
38 |
©
Danfoss | November 2021 BC265856307805en-000202

Table of Contents