4.
After the cable gland is in place remove the length A piece of the sheath and cut the braid screen
(cover) from 10 mm (distance C) from the gland bottom as shown in Figure below.
Make sure that the cable gland spring is against the cable sheath (that is protected with
copper tape) before cutting the braid screen.
Cut the braid screen
5.
Cut a piece of length D of the inner sheath shown below in the Figure Cutting the inner sheath. The
length D must equal to the length of the cable lug body.
Cutting the inner sheath
6.
Make sure that the conducting strands of the cable are completely free of silicone and other
impurities. Put the cable inside the cable lug body, and crimp the cable lug twice in different places.
See Figure below.