Bearing temperature measurement connector (optional), both ends of electric machine
1 PT100 pin
2 PT100 pin
3 PT100 ground pin
4 PT100 ground pin
Low voltage connection box details
Low voltage connection box
1 Terminal block
2 Grounding connections (M4)
3 M25 cable glands
Pin configuration of LV connections (+LVB1 option)
PIN Description
1
Temperature 1, PT100 (P), windings
2
Temperature 1, PT100 (N), windings
3
Temperature 2, PT100 (P), windings
4
Temperature 2, PT100 (N), windings
5
Temperature 3, PT100 (P), windings
6
Temperature 3, PT100 (N), windings
User Guide
EM-PMI375
Installation
©
Danfoss | November 2021 BC265856307805en-000202 | 53