FP735SI
12
GB
In the Advanced Programming mode, the following parameters can
be changed:
Parameter1 – Enable/Disable A+B Days
This allows the unit to operate in A+B days.
A and B days can be grouped arbitrarily: 5+2, 4+3, etc.
The days do not have to run in sequence.
Press + until parameter 1 is displayed.
Press V or Λ to select the required setting.
Note: A+B setting is only possible if operating mode
5+2 has been set in Advanced Programming.
WARNING: Changing this parameter will reset event
times to default values.
0 = disabled (default)
1 = enabled
Parameter 2 – Copy functions
This parameter sets the unit to operate with the
Standard Copy function or the Advanced Copy
function.
Press + until parameter 2 is displayed.
Press V or Λ to select the required setting.
Note: Advanced Copy setting is only possible if
operating mode 7 day has been set in Advanced
Programming.
0 = Standard Copy (default)
1 = Advanced Copy
Parameter 3 – Summer/winter
The Summer/winter parameter makes it possible
to let the unit change between summer and winter
period automatically or manually. The parameter can
also disable the change between summer and winter.
Press + until parameter 3 is displayed.
Press V or Λ to select the required setting.
0 = disable summer/winter change
1 = enable manual summer/winter change
2 = enable automatic summer/winter change (default)