EasyManua.ls Logo

Danfoss VLT 5000 Crane Series - Page 44

Danfoss VLT 5000 Crane Series
123 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
VL 5000 Crane
Programming
Local control
[STOP/RESET] is used for stopping the motor
connected or for resetting the frequency converter
after a drop-out (trip). Can be set to active or
inactive via parameter 014 Local stop.
If stop is activated Display line 2 will flash.
NB!:
If an external stop function is not selected and
the [STOP/RESET] key is set to inactive, the
motor can only be stopped by disconnecting
the voltage to the motor or the frequency converter.
[FWD / REV] changes the direction of rotation of
the motor, which is indicated by means of the arrow
on the display. Can be set to active or inactive via
parameter 016 Local reversing. The [FWD/REV] key
is only active when parameter 002 Local/remote
operation is set to Local control.
NB!:
Note that the fwd/rev function is not active
in crane profile. The function only functions
if the VLT is programmed to run as a normal
VLT 5000 (see parameter 512).
[START] is used to start the frequency converter. Is
always active, but cannot override a stop command.
NB!:
If the local control keys are set to inactive,
these will both become active when the
frequency converter is set to Local control
and Remote control via parameter 002 Local/remote
operation, with the exception of [FWD/REV], which
is only active in Local control.
[JOG] overrides the output frequency to a preset
frequency while the key is pressed down.
NB!:
The Jog function is not available in crane profile.
If the VLT 5000 Crane is programmed to run
as a normal VLT 5000 (see parameter 512),
the Jog function will, however, be available.
= factory setting. () = display text [] = value for use in communication via serial communication port
MG.50.N4.02 - VLT is a registered Danfoss trademark
43

Related product manuals