EasyManua.ls Logo

Danfoss VLT 5000 Crane Series - Page 78

Danfoss VLT 5000 Crane Series
123 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
VL 5000 Crane
Programming
743 MECH. SPEED N2
Value:
RPM
Depends on unit
Function:
Set the speed point for power/speed curve at N2.
Description of choice:
This parameter is limited between N1 (par. 741) speed
and output speed high limit (par. 202).
744 POWER AT N2
Value:
kW
Depends on unit
Function:
Set the output power at N2.
Description of choice:
This parameter is limited to be less than or
equal to the power at N1.
745 MECH. SPEED N3
Value:
RPM
Depends on unit
Function:
Set the speed point for power/speed curve at N3.
Description of choice:
This parameter is limited between N2 (par. 743) speed
and output speed high limit (par. 202).
746 POWER AT N3
Value:
kW
Depends on unit
Function:
Set the output power at N3.
Description of choice:
This parameter is limited to be less than or
equal to the power at N2.
747 MECH. SPEED N4
Value:
RPM
Depends on unit
Function:
Set the speed point for power/speed curve at N4.
Description of choice:
The parameter is limited between N3 (par. 745) speed
and output speed high limit (par. 202).
748 POWER AT N4
Value:
kW
Depends on unit
Function:
SetthepoweratN4.
Description of choice:
This parameter is limited to be less than or
equal to the power at N3.
749 MECH. SPEED N5
Value:
RPM
Depends on unit
Function:
Set the speed point for power/speed curve at N5.
Description of choice:
This parameter is limited between N4 (par. 747) speed
and output speed high limit (par. 202).
750 POWER AT N5
Value:
kW
Depends on unit
Function:
SettheoutputpoweratN5.
Description of choice:
This parameter is limited to be less than or
equal to the power at N4.
751 MECH. SPEED N6
Value:
RPM
Depends on unit
Function:
Set the speed point for power/speed curve at N6.
Description of choice:
This parameter is limited between N5 (par. 749) speed
and output speed high limit (par. 202).
= factory setting. () = display text [] = value for use in communication via serial communication port
MG.50.N4.02 - VLT is a registered Danfoss trademark
77