Par. No.
#
Parameter description Default value 4-set-up FC 302
only
Change during
operation
Conver-
sion index
Type
33-0* Home Motion
33-00 Force HOME [0] Home not forced 2 set-ups TRUE - Uint8
33-01 Zero Point Offset from Home Pos. 0 N/A 2 set-ups TRUE 0 Int32
33-02 Ramp for Home Motion 10 N/A 2 set-ups TRUE 0 Uint32
33-03 Velocity of Home Motion 10 N/A 2 set-ups TRUE 0 Int32
33-04
Behavior during Home Motion [0] Reverse and index 2 set-ups TRUE - Uint8
33-1* Synchronization
33-10 Synchronization Factor Master (M:S) 1 N/A 2 set-ups TRUE 0 Int32
33-11 Synchronization Factor Slave (M:S) 1 N/A 2 set-ups TRUE 0 Int32
33-12 Position Offset for Synchronization 0 N/A 2 set-ups TRUE 0 Int32
33-13 Accuracy Window for Position Sync. 1000 N/A 2 set-ups TRUE 0 Int32
33-14 Relative Slave Velocity Limit 0 % 2 set-ups TRUE 0 Uint8
33-15 Marker Number for Master 1 N/A 2 set-ups TRUE 0 Uint16
33-16 Marker Number for Slave 1 N/A 2 set-ups TRUE 0 Uint16
33-17 Master Marker Distance 4096 N/A 2 set-ups TRUE 0 Uint32
33-18 Slave Marker Distance 4096 N/A 2 set-ups TRUE 0 Uint32
33-19 Master Marker Type [0] Encoder Z positive 2 set-ups TRUE - Uint8
33-20 Slave Marker Type [0] Encoder Z positive 2 set-ups TRUE - Uint8
33-21 Master Marker Tolerance Window 0 N/A 2 set-ups TRUE 0 Uint32
33-22 Slave Marker Tolerance Window 0 N/A 2 set-ups TRUE 0 Uint32
33-23 Start Behavior for Marker Sync [0] Start Function 1 2 set-ups TRUE - Uint16
33-24 Marker Number for Fault 10 N/A 2 set-ups TRUE 0 Uint16
33-25 Marker Number for Ready 1 N/A 2 set-ups TRUE 0 Uint16
33-26 Velocity Filter 0 us 2 set-ups TRUE -6 Int32
33-27 Offset Filter Time 0 ms 2 set-ups TRUE -3 Uint32
33-28 Marker Filter Configuration [0] Marker filter 1 2 set-ups TRUE - Uint8
33-29 Filter Time for Marker Filter 0 ms 2 set-ups TRUE -3 Int32
33-30 Maximum Marker Correction 0 N/A 2 set-ups TRUE 0 Uint32
33-31 Synchronization Type [0] Standard 2 set-ups TRUE - Uint8
33-4* Limit Handling
33-40 Behavior at End Limit Switch [0] Call error handler 2 set-ups TRUE - Uint8
33-41 Negative Software End Limit -500000 N/A 2 set-ups TRUE 0 Int32
33-42 Positive Software End Limit 500000 N/A 2 set-ups TRUE 0 Int32
33-43 Negative Software End Limit Active [0] Inactive 2 set-ups TRUE - Uint8
33-44 Positive Software End Limit Active [0] Inactive 2 set-ups TRUE - Uint8
33-45 Time in Target Window 0 ms 2 set-ups TRUE -3 Uint8
33-46 Target Window LimitValue 1 N/A 2 set-ups TRUE 0 Uint16
33-47 Size of Target Window 0 N/A 2 set-ups TRUE 0 Uint16
4.3.18. 33-** MCO Adv. Settings
4. How to Program
VLT
®
Automation Drive FC 300
Instruction Manual High Power
108
MG.33.U1.22 - VLT
®
is a registered Danfoss trademark.
4

Table of Contents

Other manuals for Danfoss VLT FC 100

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT FC 100 and is the answer not in the manual?

Danfoss VLT FC 100 Specifications

General IconGeneral
BrandDanfoss
ModelVLT FC 100
CategoryDC Drives
LanguageEnglish

Related product manuals