VLT
®
FCD Series
Cable lengths and cross sections:
Max. motor cable length, screened/armoured cable .................................................................................... 10 m
Max. motor cable length, unscreened/unarmoured cable ............................................................................. 10 m
Max. cros s section to motor, see next section.
Max. cross section to control wires, rigid wire ......................................................................... 4.0 mm
2
/10 AWG
Max. cross section to control cables, flexible cable ................................................................. 2.5 mm
2
/12 AWG
Max. cross section to control cables, cable with ferrules .......................................................... 2.5 mm
2
/12 AWG
Max. cross section extra terminals for 24 V ext, T73 version, rigid cables .................................. 6.0 mm
2
/9 AWG
Max. cross section extra terminals for 24 V ext, T73 version, flexible cable ................................. 4 mm
2
/10 AWG
Max. cross section extra terminals for 24 V ext, T73 version, cable with ferrules ......................... 4 mm
2
/10 AWG
Max. cross section PE ................................................................................................................. 10 mm
2
/7 AWG
Max. cross section external PE for T73 version ......................................................................... 16 mm
2
/5AWG
If U L/cUL is to be complied w ith, cable with temperature class 60/75°C must be used. Use copper wires only.
When complying with EN 55011 1A the motor cable must be screened/armoured. See EMC emission.
Control characteristics:
Frequency range ........................................................................................................... 0.2 - 132 Hz, 1 - 1000 Hz
Resolution of output frequency ........................................................................................ 0.013 Hz, 0.2 - 1000 Hz
Repeat accuracy of Precise start/stop (terminals 18, 19) .................................................................. ±0.5msec
System response time (terminals 18, 19, 27, 29, 33) ........................................................................ 26.6 msec
Speed control range (open loop) ................................................................................. 1:15 of synchronous speed
Speed control range (open loop) <1.1 kW ............. approximately 1:10 of synchronous speed (motor dependent)
Speed control range (closed loop) ............................................................................. 1:120 of synchronous speed
Speed accuracy (open loop) <1.1 kW .................................................... 150 - 3600 rpm: Max. error of ±23 rpm
Speed accuracy (open loop) >0.75 kW .................................................... 90 - 3600 rpm: Max. error of ±23 rpm
Speed accuracy (closed loop) ................................................................. 30 - 3600 rpm: Max. error of ±7.5 rpm
All control characteristics are based on a 4-pole asynchronous motor
Surroundings:
Enclosure ........................................................................................................................... IP 66, TYPE 4x (indoor)
Enclosure T73 version ................................................................................................................... IP 65, TYPE 12
Vibration test ................................................................................................................................................. 1.0 g
Max. relative humidity ............................................................................ 95% see Air humidity in the Design Guide
Ambient temperature (FCD 335 max. 35 °C) ..................................... Max. 40 °C (24-hour average max. 35 °C)
Derating fo r ambient temperature, see special condit ions in the Design Guide
Min. ambient temperature during full-scale operation .................................................................................... 0 °C
Min. ambient temperature at reduced performance .................................................................................. - 10 °C
Temperature during storage/transport .......................................................................................... -25 - +65/70 °C
Max. altitude above sea level .................................................................................................................... 1000 m
Derating for air pressure, see special conditions in the Design Guide
EMC standards used, Emission ................................................................ EN 50081-1-2, EN 61800-3, EN 55011
EMC standards used, immunity ......................................................................................................................... EN
61000-6-2, EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6
See section on special conditions in the Design Guide
MG.04.B7.02 - VLT is a registered Danfoss trademark
112

Table of Contents

Other manuals for Danfoss VLT FCD 311

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT FCD 311 and is the answer not in the manual?

Danfoss VLT FCD 311 Specifications

General IconGeneral
BrandDanfoss
ModelVLT FCD 311
CategoryDC Drives
LanguageEnglish

Related product manuals