4 Prepare the control valve for use
4.1 Lifting conditions
WARNING
CRUSHING HAZARD
During installation or removal of a control valve, always place the unit on a stable
platform or surface that supports its assembled weight.
Failure to comply may allow the control valve to roll, resulting in death, serious injury or
equipment damage.
WARNING
LIFTING HAZARD
The lifting instructions are for installation and removal of a Daniel control valve only and
do not address lifting the control valve while it is attached or bolted to piping.
Failure to follow these instructions may result in death, serious injury or equipment
damage.
CAUTION
FORKLIFT HAZARD
Do not insert the forks of a forklift into the bore when moving the control valve.
Inserting the forks may cause the meter to become unstable, resulting in serious injury
or equipment damage.
Table 4-1: Lifting and installation conditions
Conditions Description
Ventilation and lightning Install the control valve in a well lit and ventilated location, not
less than one meter (approximately three feet) from source of
ignition or source of heat which might damage the unit.
Work area clearances and
installation height restrictions
Refer to Minimum clearances for installation, operation and
maintenance for clearances.
Surface considerations Stable surface.
Soil/floor loadings and
product/piping support
Follow local procedures that meet the standards for soil/floor
loading and product/piping support.
User manual Prepare the control valve for use
P/N 3-9008-553 November 2020
User manual 29