7
060798 • Version 1.4 • 22.01.2019
en
Functional description, continued
Manual operation
In order to change the air flow rate, defined by Automatic Demand Mode, it is possible
to select between Fan Step 0 4 manually. See the following examples:
Fan step
Function
Fan Step 0 - 4 on the unit is adjustable on the control panel.
0
The unit is turned off. It is only used due to e.g. obnoxious smells
from outside.
If the fans are disconnected for more than four hours there is a risk of
condensation in the ducts and risk of moisture damage in the unit.(all
four lamps for fan steps are turned off).
Note that Fan Step 0 is only active for four hours, after which the unit
will continue operating on Fan Step 3.
1
Can be used at night time or in absence due to e.g. holidays.
When the house is empty the ventilation can temporarily be reduced.
2
Is used at a normal demand for ventilation.
Can also be used during absence if Fan Step 1 provides too little air
change
3
Is used for a normal or high ventilation demand.
E.g. when cooking, bad, drying a larger amount of clothes, having vis-
itors and when heat waste occurs
4
Is used when a large amount of air change is needed e.g. during or
right after a party where the house needs to be thoroughly ventilated.
Note that Fan Step 4 is only active for four hours after which the unit
will continue operating on Fan Step 3.
Manual bypass
not
activated) the unit cools down by
s control, when the inside as well as the outside tempera-
o activate manual bypass in the early spring or in the autumn,
air directly to the house for
Continued overleaf