EasyManua.ls Logo

Danze Parma - Page 6

Danze Parma
20 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
®
5
Hands Free Operation Trouble Shooting Guide
There is no object within the detection range but the red light is continuously on.
• After first turning the unit on it will go into programming mode automatically for a few seconds. The light will turn off automatically
after a few seconds.
• The unit is sensing a stationary object in front of the lens. This object may not be obvious to the user. The unit will reprogram itself
and the light will turn off after a few seconds.
• If the light stays on indefinitely, the electronic module may be faulty
4.
The solenoid valve appears to be functioning incorrectly
• Check all water connections
• Check solenoid valve electronic connections
• When placing a hand in front of the sensor, check whether there is an audible “click” from the solenoid valve
• Check the filter on the solenoid valve and clean as necessary
• Change the solenoid valve
5.
The water flow is too low
• Check to make sure that the hot/cold inlet valves are fully open
• Check the filter on the solenoid valve and clean as necessary
• Check the spout nozzle and clean as necessary
6.
The mixed water does not have the desired temperature
• Turn the handle on the water mixer to change temperature – more towards the red or blue range if the mixed water temperature is
too cold or too hot.
• Check hot and cold water hoses for proper connection
7.
Hands free activated water run time
• See installation instructions
8.
© 2009 Danze, Inc. All rights reserved.