18
LOCATION 195: RESTORE / SIREN CONTROL
Location 195 is used to assign the restore/siren control characteristic for the DL250. If immediate restore (Value = 1) is
enabled the DL250 will report communicator event restores as they occur, if the restore communicator code in location 332
is selected and Report limited to once per arming (Value = 4) in this location is not enabled. If immediate restore (Value =
1) is disabled the DL250 will report communicator event restores at the end of the siren time of the zone that generated
event. If Siren limited to once per arming (Value = 2) is enabled, the DL250 will only allow one siren activation per zone, if
this feature is disabled then each zone can activate unlimited siren attempts. If Report limited to once per arming (Value
= 4) is enabled, the DL250 will limit the communicator to reporting only one alarm event per zone, the restore for that event
(if enabled) will occur on a valid disarm. Note: Regardless to when restores have been programmed to report the DL250
will only report restore if the alarmed condition physically restores. The DL250 can have one or a combination of the
characteristics listed in the restore/siren control table below. Factory default for the DL250 is "3" (1+2 = 3). This means
that the DL250 has immediate restore (Value = 1) and siren limited to once per arming (Value = 2) enabled. If restores
where to report only at disarm and siren were to be limited to once per arming then a "6" (2+4=6) would be programmed
in this location.
VALUE RESTORE CONTROL VALUE RESTORE CONTROL
1 IMMEDIATE RESTORE ENABLED 4 REPORT LIMITED TO ONCE PER ARMING
2 SIREN LIMITED TO ONCE PER ARMING 5 IMMEDIATE RESTORE ENABLED
REPORT LIMITED TO ONCE PER ARMING
3 IMMEDIATE RESTORE ENABLED
SIREN LIMITED TO ONCE PER ARMING
6 SIREN LIMITED TO ONCE PER ARMING
REPORT LIMITED TO ONCE PER ARMING
LOCATION 196: AUTO-ISOLATE ENABLE
Location 196 is used to enable the Auto Isolate feature. If a "1" is programmed in this location, the DL250 will allow the user
to enter a valid code to arm, when one or more zones are not sealed. If these zones seal before the end of either the
primary or secondary exit delays, they will arm with the remainder of the zones when the exit delay time expires. All zones
which are not sealed at the end of the exit delay will be automatically isolated. If isolated reporting has been enabled in
location 334, all automatically isolated zones will be reported to the monitoring station. When partitioning is enabled the
above table would be referred to for the correct value required in this location. For example if a "7" (1+2+4=7) was
programmed in this location and partitions were selected. Then auto isolate for partition one (Value = 1), Auto isolate for
partition two (Value = 2) and Auto isolate for partition three (Value = 4) would be enabled. Default is an "0" which disables
this feature.
VALUE AUTO-ISOLATE VALUE AUTO-ISOLATE
0 DISABLE AUTO-ISOLATE 4 ENABLE FOR PARTITION 3
1 ENABLE FOR PARTITION 1 5 ENABLE FOR PARTITION 1 & 3
2 ENABLE FOR PARTITION 2 6 ENABLE FOR PARTITION 2 & 3
3 ENABLE FOR PARTITION 1 & 2 7 ENABLE FOR PARTITION 1, 2 & 3
LOCATION 197: SILENT CODE PAD PANIC ENABLE
Location 197 is used to silence the audible output for the Code Pad Panic/Hold-Up alarm. Programming a "1" in this
location will enable the Silent mode of Code Pad Panic operation. Factory default is "0" and operation of the Code Pad
Panic (double keypress [¬] & [#]) will cause the yelp siren output to activate.
VALUE SILENT CODE PAD PANIC VALUE SILENT CODE PAD PANIC
0 AUDIBLE CODE PAD PANIC 4 ENABLE FOR PARTITION 3
1 ENABLE FOR PARTITION 1 5 ENABLE FOR PARTITION 1 & 3
2 ENABLE FOR PARTITION 2 6 ENABLE FOR PARTITION 2 & 3
3 ENABLE FOR PARTITION 1 & 2 7 ENABLE FOR PARTITION 1, 2 & 3
When partitioning is enabled the above table would be referred to for the correct value required in this location. For example
if a "7" (1+2+4=7) was programmed in this location and partitions were selected. Then silent Code pad Panic for partition
one (Value = 1), silent Code pad Panic for partition two (Value = 2) and silent Code pad Panic for partition three (Value =
4) would be enabled.