27
Locations 268-271 are used to control the communicator code for zone 4. Zone 4 is automatically enabled and when
contact I.D is selected the default report is event "130 - Burglary" with point “04" when in alarm. Refer to appendix 1 if a
different event type is required. When using Ademco High Speed, Zone 4 is defaulted to report, a "5551 5555 7" when in
alarm. Ademco High Speed is a predefined format and only the Channel number can be programmed in Data 3. The
defaults are “3:0:4:5" with telephone number 1 and the event log enabled.
LOCATION 272-275: PROGRAMMING THE COMMUNICATOR CODE FOR ZONE 5
Locations 272-275 are used to control the communicator code for zone 5. Zone 5 is automatically enabled and when
contact I.D is selected the default report is event "130 - Burglary" with point “05" when in alarm. Refer to appendix 1 if a
different event type is required. When using Ademco High Speed, Zone 5 is defaulted to report, a "5555 1555 7" when in
alarm. Ademco High Speed is a predefined format and only the Channel number can be programmed in Data 3. The
defaults are “3:0:5:5" with telephone number 1 and the event log enabled.
LOCATION 276-279: PROGRAMMING THE COMMUNICATOR CODE FOR ZONE 6
Locations 276-279 are used to control the communicator code for zone 6. Zone 6 is automatically enabled and when
contact I.D is selected the default report is event "130 - Burglary" with point “06" when in alarm. Refer to appendix 1 if a
different event type is required. When using Ademco High Speed, Zone 6 is defaulted to report, a "5555 5155 7" when in
alarm. Ademco High Speed is a predefined format and only the Channel number can be programmed in Data 3. The
defaults are “3:0:6:5" with telephone number 1 and the event log enabled.
LOCATION 280-283: PROGRAMMING THE COMMUNICATOR CODE FOR ZONE 7
Locations 280-283 are used to control the communicator code for zone 7. Zone 7 is automatically enabled and when
contact I.D is selected the default report is event "130 - Burglary" with point “07" when in alarm. Refer to appendix 1 if a
different event type is required. When using Ademco High Speed, Zone 7 is defaulted to report, a "5555 5515 7" when in
alarm. Ademco High Speed is a predefined format and only the Channel number can be programmed in Data 3. The
defaults are “3:0:7:5" with telephone number 1 and the event log enabled.
LOCATION 284-287: PROGRAMMING THE COMMUNICATOR CODE FOR ZONE 8
Locations 284-287 are used to control the communicator code for zone 8. Zone 8 is automatically enabled and when
contact I.D is selected the default report is event "130 - Burglary" with point “08" when in alarm. Refer to appendix 1 if a
different event type is required. When using Ademco High Speed, Zone 8 is defaulted to report, a "5555 5551 7" when in
alarm. Ademco High Speed is a predefined format and only the Channel number can be programmed in Data 3. The
defaults are “3:0:8:5" with telephone number 1 and the event log enabled.
LOCATIONS 288-291: DURESS COMMUNICATOR CODES
The DL250 has the ability to report a duress code when the system is armed or disarmed with user code number 15 and
a duress communicator code is enabled in Data 1. When contact I.D is selected, program Data 1 with the required event
code from appendix 1 to enable this report event. Program a "10" in Data 1 to report event "121 - Duress". When using
Ademco High Speed, program a one (1) in Data 1 to enable this report, a "1555 5555 1" Duress is reported. The
Open/Close report will accompany the Duress report complete with the user number to indicate that an Open or Close was
preformed under Duress. No restore code is reported for this event. If Data 1 is a "0", the duress capability is disabled and
user code number 15 can only be used as a standard arm/disarm code. The defaults are “0:0:0:5" with telephone number
1 and the event log enabled.
LOCATIONS 292-295: CODE PAD AUXILIARY 1 ([1] & [3]) COMMUNICATOR CODES
The DL250 has the ability to report an auxiliary 1 code and activate the priority (fire) siren each time the [1] and [3] keys are
pressed simultaneously on the Code Pad. The desired reporting code must be programmed into these locations. When
contact I.D is selected, program Data 1 with the required event code from appendix 1 to enable this report event. Program
a "1" in Data 1 to report event "110 - Fire". When using Ademco High Speed, program a one (1) in Data 1 to enable this
report, a "1555 5555 1" Duress is reported. If activated, the siren can be silenced by entering any arm/disarm code. No
restore code is reported for this event. If Data 1 is "0", the Auxiliary 1 double keypress is disabled. The defaults are “1:0:0:5"
with telephone number 1 and the event log enabled.
LOCATIONS 296-299: CODE PAD AUXILIARY 2 ([4] & [6]) COMMUNICATOR CODES