28
The DL250 has the ability to report an auxiliary 2 code and activate the pulsing buzzer each time the [4] and [6] keys are
pressed simultaneously on the Code Pad. The desired reporting code must be programmed into these locations. When
contact I.D is selected, program Data 1 with the required event code from appendix 1 to enable this report event. Program
a "11" in Data 1 to report event "100 - Medical". When using Ademco High Speed, program a one (1) in Data 1 to enable
this report, a "1555 5555 1" Duress is reported. If activated, the code pad sounder may be silenced by entering any valid
arm/disarm code. No restore code is reported for this event. If Data 1 is "0", the Auxiliary 2 double keypress is disabled. The
defaults are “1:0:0:5" with telephone number 1 and the event log enabled.
LOCATIONS 300-303: CODE PAD PANIC ([¬¬] & [#]) COMMUNICATOR CODES
The DL250 has the ability to report a Code Pad panic code and activate the burglary siren (if not selected silent) each time
the [¬] and [#] keys are pressed simultaneously on the Code Pad. The desired reporting code must be programmed into
these locations. When contact I.D is selected, program Data 1 with the required event code from appendix 1 to enable
this report event. Program a "2" in Data 1 to report event "120 - Code Pad Panic". When using Ademco High Speed,
program a one (1) in Data 1 to enable this report, a "1555 5555 1" Duress is reported. If activated, the code pad sounder
may be silenced by entering any valid arm/disarm code. No restore code is reported for this event. If Data 1 is "0", the Code
pad panic double keypress is disabled. The defaults are “2:0:0:5" with Code pad panic communicator code, telephone
number 1 and the event log enabled.
LOCATIONS 304-307: CODE PAD TAMPER COMMUNICATOR CODES
The DL250 has the ability to lock out the Code Pad for 1 minute if 30 or more key presses are made without producing a
valid code. The desired communicator code must be programmed into these locations to enable this feature. When contact
I.D is selected, program a "1" in Data 1 to report event "137 - Code Pad Tamper". When using Ademco High Speed,
program a one (1) in Data 1 to enable this report, a "5555 5551 7" Zone 8 alarm is reported. No restore code is reported
for this event. If Data 1 is "0", the Code Pad Tamper is disabled. The defaults are “1:0:0:5" with telephone number 1 and
the event log enabled.
LOCATIONS 308-311: AUTOMATIC TEST COMMUNICATOR CODES
The DL250 has the ability to send autotest reports to the base station at weekly intervals or hourly intervals from 1 to 99
hours apart. The desired communicator code must be programmed into these locations. When contact I.D is selected,
program a "1" in Data 1 to report event "602 - Auto test". When using Ademco High Speed, program a one (1) in Data 1
to enable this report, a "5555 5555 9" Auto Test. No restore code is reported for this event. If Data 1 is "0", Auto Test is
disabled. The defaults are “0:0:0:5" with telephone number 1 and the event log enabled.
LOCATIONS 312-315: FAIL TO COMMUNICATE COMMUNICATOR CODES
The DL250 has the ability to report a failed to communicate code to the base station if a report fails to get through to the
base in its pre-determined number of dial attempts. After a report has failed to communicate to the base station the DL250
will store a failed to communicate code. When the very next report is communicated to the base the failed to communicate
report will be reported. When contact I.D is selected, program a "1" in Data 1 to report event "354 - Failed to Communicate".
When using Ademco High Speed, program a one (1) in Data 1 to enable this report, a "5555 5555 9" Auto Test. No restore
code is reported for this event. If Data 1 is "0", Failed to Communicate is disabled. The defaults are “1:0:0:5" with telephone
number 1 and the event log enabled.
LOCATIONS 316-319: BOX TAMPER COMMUNICATOR CODES
The DL250 has the ability to report a box tamper if the tamper input changes from a normally closed state to open circuit.
The desired communicator code must be programmed into these locations. When contact I.D is selected, program a "1"
in Data 1 to report event "137 - Box Tamper". When using Ademco High Speed, program a one (1) in Data 1 to enable this
report, a "5555 5555 9" Auto Test. If Data 1 is "0", Failed to Communicate is disabled. The defaults are “0:0:0:5" with
telephone number 1 and the event log enabled.
LOCATIONS 320-323: AC POWER FAIL COMMUNICATOR CODES
The DL250 has the ability to report an AC power loss code to the base station after the power has been off for a selected
number of minutes from 0 to 15 (see location 330). The desired communicator code must be programmed into these
locations. When contact I.D is selected, program a "1" in Data 1 will report event "301 - AC Power Fail". When using
Ademco High Speed, program a one (1) in Data 1 to enable this report, a "1555 5555 6" AC Power Fail. If Data 1 is "0",
AC Power Fail is disabled. The defaults are “1:0:0:5" with telephone number 1 and the event log enabled.
LOCATIONS 324-327: LOW BATTERY COMMUNICATOR CODES