31
communicator event report and a “0" will disable the communicator event report.
LOCATIONS 344-347: LATE TO CLOSE COMMUNICATOR CODE
The DL250 has the ability to report a 1-3 digit late closing code to the base station, when these locations are programmed
and a closing time has been programmed into locations 368-371. When contact I.D is selected, program a "1" in Data 1 to
report event "404 - Late To Close". When using Ademco High Speed, program a one (1) in Data 1 to enable this report,
a "5555 5555 9" Auto Test. No restore code is reported for this event. If Data 1 is "0", Late To Close Communicate code
is disabled. The defaults are “0:0:0:5" with telephone number 1 and the event log enabled.
LOCATIONS 348-351: EARLY OPENING COMMUNICATOR CODE
The DL250 has the ability to report an early opening code to the base station, when these locations are programmed and
a opening time has been programmed into locations 364-367. When contact I.D is selected, program a "1" in Data 1 to
report event "400 - Early Open". When using Ademco High Speed, program a one (1) in Data 1 to enable this report, a
"5555 5555 9" Auto Test. No restore code is reported for this event. If Data 1 is "0", Early Open Communicate code is
disabled. The defaults are “0:0:0:5" with telephone number 1 and the event log enabled.
LOCATIONS 352-355: DOWNLOAD COMPLETE COMMUNICATOR CODES
Location 352-355 contains the communicator report sent each time a download session has been completed. The report
will come in after a disconnect has been made from a downloading session. When contact I.D is selected, program a "1"
in Data 1 to report event "412 - Download Complete Code". When using Ademco High Speed, program a one (1) in Data
1 to enable this report, a "5555 1555 6" Auto Test. No restore code is reported for this event. If Data 1 is "0", Download
Complete Code is disabled. The defaults are “0:0:0:5" with telephone number 1 and the event log enabled.
LOCATIONS 356-359: AUTOMATIC ARM COMMUNICATOR CODES
Location 356-359 contains the communicator report sent each time the DL250 is auto armed. When contact I.D is selected,
program a "1" in Data 1 to report event "403 - Auto Arm". When using Ademco High Speed, program a one (1) in Data 1
to enable this report, a "B444 4444 4" User 11 Closing. If Data 1 is "0", Failed to Communicate is disabled. The defaults
are “0:0:0:5" with telephone number 1 and the event log enabled. A time must also be entered into locations 368-371.
LOCATIONS 360-363: CODE PAD AUXILIARY 3 (7+9) COMMUNICATOR CODES
The DL250 will report an Aux 3 code and activate the steady buzzer output each time the [7] and [9] keys are pressed
simultaneously on the Code Pad. The desired code must be programmed in these locations. When contact I.D is selected,
program required event code from appendix 1 to enable this report event. Program a "14" in Data 1 to report event "602
- Auto Test". When using Ademco High Speed, program a one (1) in Data 1 to enable this report, a "5555 5555 9" Auto
Test is reported. No restore code is reported for this event. If Data 1 is "0", the Auxiliary 3 double keypress is disabled. The
defaults are “0:0:0:5" with telephone number 1 and the event log enabled.
LOCATIONS 364-367: EARLY OPENING TIME
The Early Opening Time is used to determine the opening time, I.E. If a user disarms the DL250 before this time, the early
to open code will be reported if enabled. User code with authorisation restriction such as “Arm Only After Closing Time” can
not Disarm the DL250 before the Early Opening Time. The Early Opening Time also marks the time the Intelligent Auto
Arming feature stop attempting the auto arm the DL250.To enable the early opening report feature a 4 digit, 24 hour
(military) opening time must be entered in locations 364 -367. For example, to enter an opening time of 8:15 A.M (08:15),
program a "0" in location 364, a "8" in location 365, a "1" in location 366, and a "5" in location 367. Factory default is a "0-6-
0-0" which sets an opening time of 6:00 A.M..