33
LOCATION 377: WEEKLY AUTO TEST ENABLE
Location 377 is used to select the day of the week, in which an autotest report will occur. Program a number from 1
(Sunday) to 7 (Saturday) for the day of the week to perform the autotest. The test will be performed at the hour specified
in locations 380-383. The default is "0" and Autotests will be performed on an hourly interval based on the settings of
locations 378 - 379. Note: The Autotest communicator code must be enabled in locations 308-311 for Autotest to report.
LOCATIONS 378-379: HOURLY AUTOTEST INTERVAL
Locations 378 - 379 are used to set the hourly autotest interval. Hourly Autotests are disabled if there are autotest day
intervals programmed in location 377. Programmed in these locations is the number hours 1 - 99 between autotest reports.
To determine when the first Auto Test will be reported, locations 452-453 “Number of elapsed hours since last autotest “
must be set. The minutes setting for this Auto Test report can be programmed in locations 382-383. Factory default is “2"-
”4". Note: The Autotest communicator code must be enabled in locations 308-311 for Autotest to report.
LOCATION 380-383: TIME TO PERFORM AUTOTEST
In these locations you program the time that you want the autotest to report. The time must be entered in a 24 hour (military)
format. For example, if the autotest time will be 23:50 the location 380 contains a '2", location 381 contains a "3" location
382 contains a "5" and location 383 contains a "0". If an autotest time of midnight is required then set these locations to
00:00. The minutes locations (382-383) will be used to determine the minutes setting when Hourly Auto Test is used in
locations 378-379. Factory default is "02:00". Note: The Autotest communicator code must be enabled in locations 308-311
for Autotest to report.
LOCATION 384: NUMBER OF EXPANSION DEVICES
Location 384 is programmed with the number of expansion devices that may be connected to the DL250. A total of seven
(7) expansion devices can be connected to the DL250, therefore, to connect 2 expansion device to the DL250 a “2" must
be programmed into this location. When expansion devises are used, the DL250 will automatically switch to the Smart Buss
mode. This means the standard 8 Zone LED code pad cannot be used with this system, and only Smart Buss compatible
code pads can be used. If a “8" is programmed in this location, the DL250 will switch to the Smart Buss mode without
requiring to see expansion devices. This feature is used when the features of the Smart buss are required ( such as viewing
the event log and change the panel clock via the LCD code pad and other Smart Buss related features) without the
programming of partitions or expansion devices. Note: expansion devices include; Wireless zone expander, 8 way relay
board, 16 way aux board, X10 interface, Printer interface, Telephone control interface (Release date: late 95), and System
event interface. Factory default is "0" no devices enabled.
LOCATION 385: EXPANDER TROUBLE COMMUNICATOR CODE
Location 385 is used to program reporting Trouble communicator code for expander devices (1 thru 7), when Contact I.D
and Ademco High Speed is selected. The Expander Trouble communicator code can be reported when an expansion
device dose not respond to the DL250 after a short period of time. When contact I.D is selected, program a one (1) in this
location to enable this report, an event "333 - Expander Trouble" will be reported. When using Ademco High Speed,
program a one (1) in Data 1 to enable this report, a "????5555 5555 9" Auto Test is reported. Default for Expander Trouble
code is “0" disabled.
LOCATION 386: EXPANDER TROUBLE PHONE SELECTOR
If a phone number other than phone #1 is desired, I.E. for dual or split reporting. A binary number must be programmed into
this location. This is derived by adding a "1" for phone #1, a "2" for phone #2 and a "4" for the internal log. Factory default
is "1" which causes Expander Trouble to report on phone #1 and internal log if the communicator event is enabled.
LOCATION 387: EXPANDER TROUBLE RESTORE COMMUNICATOR CODE
The 250 has the ability to report to the base station when the an expander device has been restored. Once the expander
device has been restored to the 250, there will be a short delay time before the restore code will be sent to the base station.
Program a "1" into this location to enable expander device restore reports. Program a "0" into this location to disable restore
reports. Default for expander device code is “0" disabled.