Location 268-271: Programming the Communicator Code for Zone 4
Locations 268-271 are used to control the communicator code for zone 4. Zone 4 is automatically enabled and when
contact ~""' I.D is selected the default report is event "130 - Burglary" with point "04" when in alarm. Refer to appendix 1 ff a
different event 4 type is required. The defaults are "3:0:4:5" with telephone number 1 and the event log enabled.
Location 272-275: Programming the Communicator Code for Zone 5
Locations 272-275 are used to control the communicator code for zone 5. Zone 5 is automatically enabled and when
contact ID is selected the default report is event "130 - Burglary" with point "05" when in alarm. Refer to appendix 1 if a
different event type is required. The defaults are "3:0:5:5" with telephone number 1 and the event log enabled.
Location 276-279: Programming the Communicator Code for Zone 6
Locations 276-279 are used to control the communicator code for zone 6. Zone 6 is automatically enabled and when
contact ID is selected the default report is event "130 - Burglary" with point "06" when in alarm. Refer to appendix 1 if a
different event type is required. The defaults are "3:0:6:5" with telephone number 1 and the event log enabled.
Location 280-283: Programming the Communicator Code for Zone 7
Locations 280-283 are used to control the communicator code for zone 7. Zone 7 is automatically enabled and when
contact ID is selected the default report is event "130 - Burglary" with point "07" when in alarm. Refer to appendix 1 if a
different event type is required. The defaults are "3:0:7:5" with telephone number 1 and the event log enabled.
Location 284-287: Programming the Communicator Code for Zone 8
Locations 284-287 are used to control the communicator code for zone 8. Zone 8 is automatically enabled and when
contact ID is selected the default report is event "130 - Burglary" with point "08" when in alarm. Refer to appendix 1 if a
different event type is required. The defaults are "3:0:8:5" with telephone number 1 and the event log enabled.
Location 288-291: Programming the Communicator Code for Zone
9
Locations 288-291 are used to control the communicator code for zone 9. Zone 9 is automatically enabled and when
contact ID is selected the default report is event "130 - Burglary" with point "09" when in alarm. Refer to appendix 1 if a
different event type is required. The defaults are "3:0:9:5" with telephone number 1 and the event log enabled.
Location 292-295: Programming the Communicator Code for Zone 10
Locations 292-295 are used to control the communicator code for zone 10. Zone 10 is automatically enabled and when
contact I.D is selected the default report is event "130 - Burglary" with point "10" when in alarm. Refer to appendix 1 if a
different event type is required. The defaults are "3:1:0:5" with telephone number 1 and the event log enabled.
Location 296-299: Programming the Communicator Code for Zone
11
Locations 296-299 are used to control the communicator code for zone 11. Zone 11 is automatically enabled and when
contact I.D is selected the default report is event "130 - Burglary" with point "11" when in alarm. Refer to appendix 1 if a
different event type is required. The defaults are "3:1:1:5" with telephone number 1 and the event log enabled.