EasyManua.ls Logo

DAS DL-300E - Arm;Disarm Codes (1-15) Summary; Master and User Code Details; User Code Partition Enable Summary

Default Icon
57 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
40
! ! ! IMPORTANT ! ! !
Before programming the OL-300E for the first time, enter the "Go To Program Code" [9][7][f][3] from the code pad,
followed by the factory default function code [9][5][0][k]. The panel defaults will now match this installation manual and you
may begin programming the control panel. When using an optional plug-in programmer which automatically enters the
programming mode, the only entry necessary is [9][5][0][x] to load factory defaults.
ARM/DISARM CODES 1-15
LOCATION PAGE DESCRIPTION DATA 1 DATA 2 DATA 3 DATA 4 “DEFAULT”
000-003 9 USER #1 ARM/DISARM CODE (MASTER) “1-2-3-4”
004-007 9 USER # 2 ARM/DISARM CODE “15” DISABLED
008-011 9 USER # 3 ARM/DISARM CODE “15” DISABLED
012-015 9 USER # 4 ARM/DISARM CODE “15” DISABLED
016-019 8 USER # 5 ARM/DISARM CODE “15” DISABLED
020-023 8 USER # 6 ARM/DISARM CODE “15” DISABLED
024-027 8 USER # 7 ARM/DISARM CODE “15” DISABLED
028-031 8 USER # 8 ARM/DISARM CODE “15” DISABLED
032-035 8 USER # 9 ARM/DISARM CODE “15” DISABLED
036-039 8 USER # 10 ARM/DISARM CODE “15” DISABLED
040-043 8 USER # 11 ARM/DISARM CODE “15” DISABLED
044-047 8 USER # 12 ARM/DISARM CODE “15” DISABLED
048-051 8 USER # 13 ARM/DISARM CODE “15” DISABLED
052-055 8 USER # 14 ARM/DISARM CODE “15” DISABLED
056-059 8 USER # 15 ARM/DISARM CODE “15” DISABLED
060-063 8 GO TO PROGRAM ACCESS CODE “9-7-1-3”
ENABLING ARM/DISARM CODES 1-16 BY PARTITION (OPTIONAL)
LOCATION PAGE DESCRIPTION DATA "DEFAULT"
64 9 PARTITION(S) FOR USER # 1 ARM/DISARM CODE '15' ALL
65 9 PARTITION(S) FOR USER # 2 ARM/DISARM CODE CE' ALL
66 9 PARTITION(S) FOR USER # 3 ARM/DISARM CODE '15'ALL
67 9 PARTITION(S) FOR USER # 4 ARM/DISARM CODE '15' ALL
68 9 PARTITION(S) FOR USER # 5 ARM/DISARM CODE '15'ALL
69 9 PARTITION(S) FOR USER # 6 ARM/DISARM CODE '15' ALL
70 9 PARTITION(S) FOR USER # 7 ARM/DISARM CODE '15'ALL
71 9 PARTITION(S) FOR USER # 8 ARM/DISARM CODE '15'ALL
72 9 PARTITION(S) FOR USER # 9 ARM/DISARM CODE '15'ALL
73 9 PARTITION(S) FOR USER # 10 ARM/DISARM CODE '15'ALL
74 9 PARTITION(S) FOR USER # 11 ARM/DISARM CODE '15' ALL
75 9 PARTITION(S) FOR USER # 12 ARM/DISARM CODE '15'ALL
76 9 PARTITION(S) FOR USER # 13 ARM/DISARM CODE '15'ALL
77 9 PARTITION(S) FOR USER # 14 ARM/DISARM CODE '15'ALL
78 9 PARTITION(S) FOR USER # 15 ARM/DISARM CODE '15' ALL
79 PARTITION(S) FOR “GO TO PROGRAM” ACCESS CODE '15' ALL
PARTITIONED SYSTEMS NON PARTITIONED SYSTEMS
VALUE CHARACTERISTIC VALUE CHARACTERISTIC
1 Partition #1 1 Standard Arm/Disarm Code
2 Partition #2 2 Arm Only After Closing Time
4 Partition #3 4 Arm Only Code
8 Partition #4 8 Open/Close Reports For User

Table of Contents