Loading...
Scale Error Reporting
Technical Guide 3-7
-0- Off
Cannot zero at power- up or
weight remains on scale for
more than 2 minutes or
weight has not returned to
zero between POS weight
requests
a
.
- Check debris chutes.
- Verify that the weigh platter moves
freely.
- Remove item(s) from scale
- Press Scale Zero Push Button
- for more information.
- If the scale still fails to zero, recali-
brate the scale.
a. This is a configurable feature.
Remote
Display
Scale Status
Lamp
Problem
Description
Action Required