Motion Test
Technical Guide 4-3
Motion Test
This test verifies that the scale will not ‘zero’ when the weighing surface of
the scanner/scale is in motion.
1. Verify that the Yellow LED
1
is on and the Remote Display reads
0.000 kilograms.
2. Press lightly on the weigh platter of the scanner/scale with one hand
and at the same time press and release the Zero Push Button on the
operator’s panel. The Yellow LED should turn Off and the Remote
Display should not display 0.000 kilograms.
3. Remove your hand from the weighing platform and verify that the
Yellow LED is On and the Remote Display reads 0.000 kilograms.
1. Yellow LED indications can be configured via feature programming and may not be enabled for
certain functions.

Table of Contents

Other manuals for Datalogic MAGELLAN 8300

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic MAGELLAN 8300 and is the answer not in the manual?

Datalogic MAGELLAN 8300 Specifications

General IconGeneral
Read rate (max)3900 reads/s
Decoding standards1D, GS1 DataBar
Standard interfacesKeyboard Wedge, RS-232
USB 2.0 ports quantity1
Input voltage100 - 250 V
Product colorMetallic
Storage temperature (T-T)-40 - 70 °C
Operating temperature (T-T)10 - 40 °C
Operating relative humidity (H-H)5 - 95 %
Weight and Dimensions IconWeight and Dimensions
Depth102 mm
Width292 mm
Height130 mm

Related product manuals