EasyManuals Logo

Datalogic MAGELLAN 8400 Quick Reference Sheet

Datalogic MAGELLAN 8400
2 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
1x
1x
1x
1x
Magellan
TM
83/8400 Calibration Process Quick Reference Sheet
1 2 3 4
5 6 7 8
Ensure that the Scanner-
Scale is powered-on (the
green top LED and orange
>0< button will be lit or
flashing).
Return the wire lift handle
to its down position and
replace the Top Platter. (If
the Top Platter does not
seat correctly, recheck to
see that the lift handle is
fully retracted.)
After ensuring the platter
is fully seated, press &
release the flashing >0<
button once. Wait for the
scanner to sound two
beeps. (The >0< button
will continue to flash.)
Place 20 lbs. of certified
weights on the platter and
press & release the >0<
button once. The scanner
will emit a trill sound upon
registering the weight.
Remove the weights from
the platter and press &
release the >0< button once
to complete the calibration
sequence. The scanner will
reset and the >0< button
will light steadily.
Remove the Top Platter
from the scanner-scale,
and locate the switch
door.
Open the calibration door
cover by pushing back
towards the optics
chassis. (It may be
necessary to push the
wire lift handle into the
upright position to access
the cover.)
Use your finger to reach
inside the calibration bay,
locate the small plunger
switch and press &
release it once. The
scanner will issue seven
rapid beeps and the >0<
button will begin to flash.
www. datalogic.com
© 2013 Datalogic, Inc. • All rights reserved.
Datalogic and the Datalogic logo are registered trademarks of Datalogic S.p.A. in many countries, including the U.S.A. and the E.U.

Other manuals for Datalogic MAGELLAN 8400

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic MAGELLAN 8400 and is the answer not in the manual?

Datalogic MAGELLAN 8400 Specifications

General IconGeneral
Read rate (max)5200 reads/s
Tilt angle range360 - 360 °
Decoding standards1D/GS1
Standard interfacesUSB, RS-232
Power requirements100 - 250V
Dimensions (WxDxH)102 x 356 x 130 mm
CertificationRoHS, EN, IEC
Product colorGrey, Silver
Storage temperature (T-T)-40 - 70 °C
Operating temperature (T-T)-10 - 40 °C
Operating relative humidity (H-H)5 - 95 %