11
Fig.5
Region 2
For the width, calculate the following:
The distance between J to K (730mm) divided by the distance between I to K (2500mm) multiplied
by the source width (1920).
(730 ÷ 2500) x 1920 = 561
Input the number 561 as the Width for Region 2.
To calculate the height of Region 2:
Measure the active screen area between M and J
In this example M to J = 448mm.
The distance between M to J (448mm) divided by the distance between A to C (1500mm) multiplied
by the source height(1080).
(448 ÷ 1500) x 1080 = 323
Input the number 323 as the Height for Region 2.
To calculate the Top number for Region 2:
Measure the distance from B to M (inside bezels).
In this example B to M = 372mm.
Calculate the following:
The distance between B to M (372mm) divided by A to C (1500mm) multiplied by the source height
(1080).
(372 ÷ 1500) x 1080 = 266
Enter 266 into the Top box for Region 2.
To calculate the Left number for Region 2:
Measure the distance from I to K (inside bezels).
In this example I to K = 2500mm.
Calculate the following:
The distance between I to K (2500mm) minus the distance between J to K (730mm) divided by I to K
(1500mm) multiplied by the source width (1920).
(2500 - 730) ÷ 2500 x 1920 = 1360
Enter 1360 into the Left box for Region 2.