EasyManua.ls Logo

Datapath X4 - Setting up the x4; Connection and Power-Up Procedure; Input Signal Monitoring and Adjustment

Datapath X4
14 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Region 4
For the width, calculate the following:
The distance between C to D (730mm) divided by the distance between I to K (2500mm) multiplied
by the source width (1920).
(730 ÷ 2500) x 1920 = 561
Input the number 561 as the Width for Region 4.
For the height, calculate the following:
Measure the active screen area between N and C
In this example N to C = 730mm.
The distance between N to C (730mm) divided by the distance between A to C (1500mm) multiplied
by the source height(1080).
(730 ÷ 1500) x 1080 = 526
Input the number 526 as the Height for Region 4.
To calculate the Top number for Region 4
Measure the distance from A to C (inside bezels).
In this example A to C = 1500mm.
Calculate the following:
The distance between A to C (1500mm) minus the distance between C to N (730mm) divided by A
to C (1500mm) multiplied by the source height (1080).
(1500 - 730) ÷ 1500 x 1080 = 554
Enter 554 into the Top box for Region 4.
Alternatively, simply subtract the the previously calculated region height (526) from the known input
canvas height:
1080 - 526 = 554 lines
To calculate the Left number for Region 4:
Measure the distance from I to N (inside bezels).
In this example I to N = 730mm.
Calculate the following:
The distance between I to N (730mm) divided by I to K (2500mm) multiplied by the source width
(1920).
(730 ÷ 2500) x 1920 = 561
Enter 561 into the Top box for Region 4.