Step 1. Pick up phone and press “****” to start IVR
Step 2. Choose “4”, and CDS-9090 report current gateway
Step 3. Input the new gateway and with the end char #
using “*” to replace “.”, user can input 192*168*20*1 to set the new gateway 192.168.20.1
press # (pound) key to indicate that you have finished
3) Report “operation successfulif user operation properly.
Note: If you want to quit by the wayside, press “**”.
Step 1. Pick up phone and press “****” to start IVR
Step 2. Choose “5”, and CDS-9090 report current DNS
Step 3. Input the new DNS and with the end char #
using “*” to replace “.”, user can input 192*168*20*1 to set the new gateway 192.168.20.1
press # (pound) key to indicate that you have finished
3) Report “operation successfulif user operation properly.
If you want to quit by the wayside, press “**”.
Step 1 .Pick up phone and press “****” to start IVR
Step 2. Choose “6”, and CDS-9090 report “Factory Reset”
Step 3. Prompt "Please enter password", the method of inputting password is the same as operation 1.
If you want to quit by the wayside, press “*”.
Step 4. Prompt “operation successfulif password is right and then CDS-9090 will be factory setting.
Step 5. Press “7” reboot to make changes effective.
Step 1. Pick up phone and press “****” to start IVR
Step 2. Choose “7”, and CDS-9090 report “Reboot”
Step 3 .Prompt "Please enter password", the method of inputting password is same as operation 1.
Step 4. CDS-9090 will reboot if password is right and operation is properly.
Step 1. Pick up phone and press “****” to start IVR
Step 2. Choose “8”, and CDS-9090 report “WAN Port Login”
Step 3. Prompt "Please enter password", the method of inputting password is same as operation 1.
If you want to quit by the wayside, press “*”.
Step 4. Report “operation successfulif user operation properly.
Step 5. Prompt “1enable 2disable”,choose 1 or 2, and with confirm char #
Step 6. Report “operation successfulif user operation properly.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DataRemote Pots In a Box CDS-9090 and is the answer not in the manual?

DataRemote Pots In a Box CDS-9090 Specifications

General IconGeneral
BrandDataRemote
ModelPots In a Box CDS-9090
CategoryWireless Router
LanguageEnglish

Related product manuals