TYMSERVE 2000
as when first coming up or after an extended period
when no primary reference source is available."
::= {ntpVars 1}
ntpMode OBJECT-TYPE
SYNTAX INTEGER {
unspecified(0),
symmetricactive(1),
symmetricpassive(2),
client(3),
server(4),
broadcast(5),
reservedcontrol(6),
reservedprivate(7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"NTP association mode. This is an integer
indicating the association mode, with values
coded as follows:
============================================
0 unspecified
1 symmetric active
2 symmetric passive
3 client
4 server
5 broadcast
6 reserved for NTP control messages
7 reserved for private use
============================================
NOTE: In the Datum TS2000 series, this value is
currently ALWAYS set to 4 (server only)."
::= {ntpVars 2}
ntpStratum OBJECT-TYPE
SYNTAX INTEGER (0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current NTP stratum level. This is an integer
indicating the stratum of the local clock with
values defined as follows:
================================================
0 unspecified
1 primary reference (e.g., calibrated atomic
clock, radio clock)
2-255 secondary reference (via NTP)
Datum Inc, Bancomm Div. TYMSERVE 2000 Manual
xli