Setup Mode
16
Screen 9: Daylight Savings Status
Use this screen to either verify the correct automatic Daylight Savings sta-
tus or to set Daylight Savings manually.
Screen 9: Daylight Savings Status
1. Press the up and down arrows to turn Daylight Savings Time on or off
on the appropriate days of the year, if Day Savings setting is MANUAL.
If you have an AUTO Daylight Savings setting, the console display the
appropriate setting based on the current time and date.
2. Press DONE to move to the next screen.
Screen 10: Elevation
Meteorologists standardize barometric pressure data to sea level so that
surface readings are comparable, whether they’re taken on a mountainside
or by the ocean. To make this same standardization and ensure accurate
readings, enter your elevation in this screen.
Screen 10: Elevation
Note: If you do not know your elevation, there are several ways to find out. Many atlases
and almanacs include elevation for cities and towns. You can also check with the ref-
erence department of your local library. The more accurate you are, the better; but a
reasonable estimate works too.
07395.234 Manual VP2 console Book.book Page 16 Wednesday, November 17, 2004 3:57 PM

Other manuals for Davis Instruments Vantage Pro2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Davis Instruments Vantage Pro2 and is the answer not in the manual?

Davis Instruments Vantage Pro2 Specifications

General IconGeneral
Update Interval2.5 seconds
Wind Direction Resolution
Wind Direction Range0 to 360°
Rain CollectorSelf-emptying tipping bucket
UV Index Range0 to 16
Solar Radiation Range0 to 1800 W/m²
Console DisplayLCD with backlight
Wireless Transmission Range1000 feet (300 meters) line of sight
Temperature Range-40 to 150 °F (-40 to 65 °C)
Humidity Range1 to 100%
Barometric Pressure Range16.00 to 32.50 inHg (540 to 1100 hPa)
Wind Speed Range0 to 200 mph (0 to 322 km/h)
Rain Collector Size0.01 inch (0.2 mm) resolution
Rain Measurement Accuracy±4% at rates up to 2 in/hr (50 mm/hr)
Power SupplySolar-powered with battery backup
Console Power SupplyAC adapter or 3 C batteries