202 RR
Operating instructions and warnings
26
PROCEDURE DESCRIPTION
PROCEDURE
P001
Positioning of leaf M1
P002
Positioning of leaf M2
P003
Memorization of the motors’ stroke
P004
Deletion of the radio receiver memory
P005
Transmitters memorizing
P006
Search and deletion of a transmitter
P007
Resetting of default parameters
PARAMETER DESCRIPTION
SETTABLE VALUES
1
USER
2
PARAMETRES
P008
Type of coding of the radio receiver
000
HCS fixed part only
001
HCS rolling code
002
HT12E dip switch
P009
Channel selection and linking to “start” and “pedestrian” inputs
start
pedes-
trian
start
pedes-
trian
001
CH1 CH2
009
CH3 CH4
002
CH1 CH3
010
CH4 CH1
003
CH1 CH4
011
CH4 CH2
004
CH2 CH1
012
CH4 CH3
005
CH2 CH3
013
CH1 CH2
3
006
CH2 CH4
014
CH2 CH2
3
007
CH3 CH1
015
CH3 CH2
3
008
CH3 CH2
016
CH4 CH2
3
P010
Motor speed during normal stroke, calculated as % of max speed (with encoder). This
figure is not considered, max speed during the run
50...................................100
P011
Motor speed during slow down, calculated as % of max speed (with encoder). This figure is
not considered, slow down speed fixed (without encoder)
30.................60...........................100
P012
Slow-down duration of M1 (expressed as % of total stroke)
10......25
.............50
P013
Slow-down duration of M2 (expressed as % of total stroke)
10......25
.............50
P014
Operator 1 force while opening (with
encoder)
Operator 1 force (without encoder)
30.....................................90
..100
P015
Operator 1 force while closing (with encoder) Not used (without encoder)
30.....................................90
..100
P016
Operator 2 force while opening (with encoder) Operator 2 force (without encoder)
30.....................................90
..100
P017
Operator 2 force while closing (with encoder) Not used (without encoder)
30.....................................90
..100