P018
Selection of type of external safety device: rib / barrier. If the ribs are activated the
movement direction of both motors is inverted; during slow-down phase, the activation
is interpreted as stroke end. If the barrier is activated the movement of both motors is
stopped.
000
safety ribs
001
photoelectric barriers
P019
Time of automatic closing (expressed in sec). If = 0 the automatic closing is deactivated
0 20
..................................................................255
P020
Time of pre-flashing (expressed in sec)
0
..............................................................................15
P021
Time of phase displacement in opening (expressed in sec) ATTENTION: if=0 the exit
which controls the electric lock is automatically deactivated
0....................................................10
P022
Time of phase displacement in closing (expressed in sec)
0.............3
...................................10
P023
Collectivity function: if it is activated it deactivates both start and pedestrian inputs for
the whole duration of automatic opening and closing
000
deactivated
001
activated
P024
Ram blow function: if it is activated, it pushes the motors close for one second before
each opening movement, so as to ease the releasing of any electric lock
000
deactivated
001
activated
P025
Operating program: reversal (start->open, start->close, start->open ...), step-by-step
(start->open, start->stop, start-close...)
000
inversione
001
step-by-step
P026
FOTO 1 Photocell function even while opening: if it is activated, the photocell stops
the movement while opening until the obstacle is removed. In any case it reverses the
direction of movement while closing
000
Photocell activated only in
closing
001
Photocell activated also in
opening
P027
Clean contact operation :
- If = 0, open gate warning light, the contact is always closed when the gate is opened,
it opens again only when the closing movement is completed
- If different from 0, courtesy light, the contact is closed during every movement, it opens
again when the motor stops according to a pre-settable delay (expressed in sec)
0
..........................................................................255
P028
Unused parameter
P029
One motor function: if it is activated, the control board controls motor 1 only
ATTENTION: activate this function before memorizing motor’s stroke.
ATTENTION: When 1 motor is working (P029=1) set P022=0
000
deactivated
001
activated
P030
PED input operation:
If=0 PED input starts the pedestrian opening (operator n.1 only)
If=1 PED input starts the closing, START input starts the opening.
000
Pedestrian
001
Separated Open/Close