202 RR
Operating instructions and warnings
28
P031
Adjustment of motor force when it reaches the end of stroke while closing - If=0,
adjustment is disabled (force level is equal to the one set during all closing run) -
If0 (operators with encoder) it indicates the force value set in the last length. If0
(operators without encoder), max speed is activated during last length.
0............................................................................100
P032
Unused parameter
P033
Unused parameter
P034
Operator selection with or without encoder.
WARNING: correctly set this function before the operators run learning
WARNING: remind to correctly position even the Jumpers J8 and J10 (see table1).
000
Operator with built in encoder
001
Without encoder. Slow down is
activated.
002
Without encoder. Slow down
not activated.
1
The default value, set by manufacturer at the factory, is written in bold and underlined.
2
Column reserved to the installer to fill in with the automation personalised parameters Table 2 Parametres